Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-798
EXP-INTF (Expansion Interface Circuit Pack) 
9
If the red LED remains lit, see the Note under 
‘‘Expansion Interface LEDs’’
 above.
Expansion Interface Manual Loopback Procedure
This procedure is to be used when an Expansion Interface circuit pack cannot be 
tested by software. This is usually when the Expansion Interface circuit pack is in 
the EPN and the EPN is down. When the connection to the Expansion Interface 
circuit pack is via fiber, a short length of optical fiber is required for this 
procedure. If a metallic cable is used in the connection, the metallic connector 
must be removed from the back of the carrier, and a lightwave transceiver 
connected in its place. The short length of optical fiber can then be used.
If this procedure is run on both endpoints of a fiber link (Expansion Interface 
circuit packs or Switch Node Interface circuit packs), and both check out fine, 
then the failure is most likely in the fiber itself, assuming neither endpoint circuit 
pack is busied out and the link remains inactive.
1. Busyout the circuit pack (Expansion Interface or Switch Node Interface) 
using the busyout board UUCSS command.
2. Disconnect the transmit and receive fiber pair from the lightwave 
transceiver on the back of the circuit pack (Expansion Interface or Switch 
Node Interface) slot.
NOTE:
The fiber connected to the transmit side of the lightwave transceiver 
on one Expansion Interface circuit pack should be connected to the 
receive side of the lightwave transceiver on the circuit pack on the 
opposite end of the fiber.
3. Using a fiber jumper cable, interconnect the transmit and receive jacks of 
the lightwave transceiver as shown in 
NOTE:
Make sure that the total length of the fiber jumper cable does not 
exceed the maximum length recommended for the fiber link 
connections between cabinets. Using cable lengths not within 
connectivity guidelines can adversely affect test results.
4. Go to the front of the cabinet and inspect the yellow LED.
If the yellow LED flashes on at a rate of once per second, the 
(Expansion Interface or Switch Node Interface) circuit pack or 
transceiver should be replaced.
If the yellow LED flashes on at a rate of five times per second, the 
circuit pack (Expansion Interface or Switch Node Interface) or the 
lightwave transceiver may need replacement. This condition may 
also be due to a faulty system clock on the network containing this 
Expansion Interface circuit pack.