Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-1040
MET-LINE (MET Line) 
9
Error Log Entries and Test to Clear Values
Notes:
a. The data link between the port and the terminal is not operational, i.e., the 
port circuitry has detected an off-board problem. Verify that the MET set is 
connected and that the Electronic Power Feed (EPF) test passes. If data 
transmission problems are experienced, check for defective wiring or a 
defective voice terminal, or move terminal electrically closer to the switch 
(i.e., reduce the length of the wiring between the terminal and the switch). 
If the problem persists, replace the circuit pack. Once the problem is 
resolved, the system retires the alarm after a predetermined time delay.
Table 9-411. MET Line Error Log Entries
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
0
1
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate
test description and follow the recommended procedures.
0
Any
Any
Any
test port UUCSSpp sh r 1
1 (a)
40987
None
18 (b)
0
busyout port 
UUCSSpp
WARNING
OFF
release port UUCSSpp
130 (c)
None
WARNING
ON
test port UUCSSpp sh
257 (d)
40988
None
MIN/WRN
2
2.
Major or Minor alarms MO may be downgraded to Warning alarms based on the values used in the set
options
 command.
OFF
513 (e)
40965
Hybrid Line Station 
Audits Test (#61)
WARNING
OFF
test port UUCSSpp sh r 4
769
Port Diagnostic Test 
(#35)
MIN/WRN
2
ON
test port UUCSSpp l r 3
1025
Hybrid & Conf. 
Circuits Test (#57)
MIN/WRN
2
ON
test port UUCSSpp l r 3
1537 (f)
40968
None
MIN/WRN
2
OFF
1793
TDM NPE Crosstalk 
Test (#6
MIN/WRN
2
ON
test port UUCSSpp l r 3
2049 (g)
32770
2049 (h)
40967
3840 (i)
40989