Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-1041
MET-LINE (MET Line) 
9
b. Error type 18 is logged when maintenance personnel busyout the port. 
maintenance personnel. The port is released from busyout via the release 
port UUCSSpp
 command.
c. The circuit pack has been removed or has been insane for more than 11 
minutes. To clear the error, reinsert or replace the circuit pack.
d. The EPF has been turned off due to an overcurrent condition at the voice 
terminal. Check for defective wiring or a damaged jack, and verify that the 
voice terminal is an MET set. Once the problem is resolved, the system 
retires the alarm after a predetermined time delay.
e. The EPF inquiry audit has returned ‘‘epf-no-load’’ messages. This usually 
indicates that the voice terminal has been disconnected or that there is a 
defect in the wiring to the terminal. Check out both possibilities.
When the EPF inquiry audit subsequently receives an ‘‘epf-on-ok’’ or an 
‘‘epf-off-ok’’ message, the system will take action to retire the alarm.
f. The port has reported a problem with the data link to the voice terminal. 
Ignore this error if there are no complaints about the voice terminal. 
Otherwise, make sure the voice terminal is connected, check for defective 
wiring, check for a defective voice terminal, and decrease the length of 
the wiring between the voice terminal and the switch. If the problem 
persists, replace the circuit pack.
g. The voice terminal went off-hook while it was in the ready-for-service state. 
Use the status system command to determine the state of the voice 
terminal. The off-hook should have moved the station to in-service. No 
repair action is necessary.
h. This code is generated when the link between the circuit pack and the 
voice terminal is successfully reset. No repair action is necessary.
i. The hardware sent an uplink message indicating that the Electric Power 
Feed (EPF) is not loaded, that is, it is not currently supplying power to a 
voice terminal. No repair action is necessary.
System Technician-Demanded Tests: Descriptions 
and Error Codes
Always investigate tests in the order presented in the table below whe
inspecting errors in the system. By clearing error codes associated with the 
Port 
Diagnostic Test, for example, you may also clear errors generated from other 
tests in the testing sequence.