Lucent Technologies Release 7 User Manual
DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-1071
MMI-PT
9
MMI-PT
NOTE:
Refer to
Chapter 5, ‘‘Alarms, Errors, and Troubleshooting’’
troubleshooting information.
The Multimedia Interface Circuit Pack provides a number of H.221 protocol
terminations for bit streams received from the TDM bus. The Multimedia Interface
demultiplexes the H.221 bit stream (audio, video, data, control, and indication
signals) and transmits the bit streams onto the TDM bus to be processed by the
appropriate circuit packs.
terminations for bit streams received from the TDM bus. The Multimedia Interface
demultiplexes the H.221 bit stream (audio, video, data, control, and indication
signals) and transmits the bit streams onto the TDM bus to be processed by the
appropriate circuit packs.
Each Multimedia Interface Circuit Pack contains 32 separately maintained
“ports,” more commonly referred to as "resources." MMI-PT represents one of
these 32 resources. At system boot or when the circuit pack is inserted, 32
resources are inserted into the system.
“ports,” more commonly referred to as "resources." MMI-PT represents one of
these 32 resources. At system boot or when the circuit pack is inserted, 32
resources are inserted into the system.
The MMI circuit pack contains 4 Digital Signal Processors (DSPs) which manage
the 32 resources. These resources are directly mapped to DSPs:
the 32 resources. These resources are directly mapped to DSPs:
All 8 resources that the circuit pack controls may be placed out of service by the
failure of one of these DSPs.
failure of one of these DSPs.
MO Name (in
Alarm Log)
Alarm
Level
Initial Command to Run
1
1.
Where UU is the universal cabinet number (1 for PPN and 2-44 for EPN); C is the carrier
designation (for example, A, B, C, D, or E); SS is the address of the slot in the carrier where the
circuit pack is located (for example, 01, 02, ...); and pp is the two digit port number (01, 02, 03, ...).
designation (for example, A, B, C, D, or E); SS is the address of the slot in the carrier where the
circuit pack is located (for example, 01, 02, ...); and pp is the two digit port number (01, 02, 03, ...).
Full Name of MO
MMI-PT
MAJOR
test port UUCSSpp l r#
Multimedia Interface Port
MMI-PT
MINOR
test port UUCSSpp l r#
Multimedia Interface Port
MMI-PT
WARNING
test port UUCSSpp l r#
Multimedia Interface Port
Resource
Direct Map
1-8
DSP1
9-16
DSP2
17-24
DSP3
25-32
DSP4