Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-1073
MMI-PT 
9
Error Log Entries and Test to Clear Values
Notes:
a. The customer endpoint connected on a conference sent too many 
messages to the VSP-MCU in a specified amount of time. Check the 
“status conference” forms to correlate which customer had the problem. 
This is a customer endpoint problem and not a VSP-MCU problem.
b. This port has been busied out by the busyout port UUCSSpp command.
c. Indicates that the circuit pack has been removed or has been insane for 
more than 11 minutes. To clear the error, replace or reseat the circuit pack.
d. This error occurs if the MMI circuit pack detects a DSP Error. Maintenance 
software will reset the DSP when this error is received. This error is logged 
for all 8 resources connected to this particular DSP. If this DSP continues 
to fail sanity, a Minor alarm is raised. Replace the circuit pack. 
e. This error occurs when the Resource Looparound Test (#1111) fails. Run 
the Long Test Sequence and note the results of Test #1111.
f. This error occurs if either the MMI or Voice Conditioner (VC) circuit packs 
reports a loss of framing on the service channel between these two circuit 
packs. When a customer endpoint establishes a call to the VSP-MCU, a 
channel is established between the MMI resource and the VC port. If this 
channel is detected to go down by either circuit pack, an uplink message 
is sent. This error is then forwarded to maintenance for both circuit packs. 
Run the Long Test Sequence for this MMI resource, and if any of the tests 
Table 9-427.
MMI-PT Error Log Entries 
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/ Off 
Board
Test to Clear Value
0
1
1.
Run the short test sequence first. If all tests pass, run the Long Test Sequence. Refer to the 
appropriate test description and follow the recommended procedures.
0
Any
Any
Any
test port UUCSSpp sh r 1
1 (a)
Any
Uplink error from pack
18 (b)
0
Busyout port PCSSpp
WNG
OFF
release port UUCSSpp
130 (c)
Any
Software generated
WNG
ON
257 (d)
Any
None
MAJ/
MIN
ON
513 (e)
Any
Resource Loopback 
Test (#1111)
MIN
ON
test port UUCSSpp sh r 3
1025 (f)
Any
Uplink error from pack
3841 - 
3844 (g)
Any
Uplink error from pack