Lucent Technologies Release 7 User Manual
DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-1096
M/T-ANL (Maintenance/Test Analog Port)
9
Error Log Entries and Test to Clear Values
Notes:
a. This error code appears in the Error Log only if the MTB circuit pack has
been removed since the Error Log was last cleared. Verify that the circuit
pack has been reinserted.
pack has been reinserted.
b. This error indicates a hardware failure on the Analog Port circuitry.
Replace the Maintenance/Test circuit pack if the alarm is not resolved by
the command above.
the command above.
c. This error indicates that call processing records did not agree with
on-board records for the hook state (on-/off-hook) of the Maintenance/Test
Analog Port. This error is not service-affecting and no action is required.
Analog Port. This error is not service-affecting and no action is required.
Table 9-435.
M/T-ANL Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
(a)
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate
test description and follow the recommended procedures.
test description and follow the recommended procedures.
0
Any
Any
Any
test port UUCSSpp
1 (b)
41018
none
MINOR
ON
test port UUCSSpp l r 3
18
0
busyout port UUCSSpp
WARNING
OFF
release port UUCSSpp
257
Any
NPE Crosstalk test (#9)
MINOR
ON
test port UUCSSpp l r 3
513
Any
Analog Port Sanity Test
(#963)
(#963)
MINOR
ON
test port UUCSS01 r 2
769
Any
Analog Port Digital
Looparound Test (#13)
Looparound Test (#13)
MINOR
ON
test port UUCSSpp r 3
3840(c)
Any
Hook State Inquiry test
(#566)
(#566)