Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-1173
PDMODULE (Processor Data Module) TDMODULE (Trunk Data Module) 
9
For this test to run, the ‘‘Remote Loop-Around Test’’ field on the Data Module 
administration form must be set to ‘‘y,’’ indicating that the data module endpoint 
supports the test.
Figure 9-73.
Internal Looparound Test
A signaling message is sent through the digital port circuit pack to the data 
module, requesting it to enter loop-around mode. A test pattern is then sent from 
the TN771 Maintenance/Test circuit pack, over the path illustrated above, and 
back to the TN771 where it is checked for consistency.
The test aborts if any of the following local PBX resources are not available: a 
digital port on the TN771 (there are two such digital ports, but only one may be 
used at a time), two TDM time slots and an idle digital port connected to the data 
module.
Digital Line
Circuit Pack
Data
Equipment
Data Module
(MPDM, DA,
MTDM)
G3r PBX
TN771
Maintenance/
Test Circuit
Pack
TDM Bus