Maintenance Object Repair Procedures 
9-1175
PDMODULE (Processor Data Module) TDMODULE (Trunk Data Module) 
9
1392
ABORT
This port is currently a TTI port and the test will not execute on it.
1. Verify that the port is a TTI port using either the display port command (the 
display shows that the port is a TTI port) or the list config command (the 
display shows a "t" for the port).
2. If either list config or display port indicate that the port is not a TTI port, 
escalate the problem. If both commands indicate that the port is a TTI port, 
the abort is correct for the test, and no action is necessary.
2005
ABORT
The handshake between the Maintenance/Test digital port and the Data 
Module failed.
1. Look for M/T-DIG errors in the Error Log. If present, refer to "M/T-DIG 
(Maintenance/Test Digital Port)" section.
2. If test still aborts on retry, check physical connection of data module under 
test. Make sure the switches are on NORM, OFF (between REM_LP and 
LOC_LP), 9600, and ASYN.
3. If the test still aborts, replace the Data Module.
2312
ABORT
The Looparound Test did not complete, failed to receive loop-back data.
1. Check for M/T-DIG error in the Error Log. If present, refer to M/T-DIG 
section.
2. Retry the test, if still aborts, replace the Data Module.
3. If the test aborts again, replace the Digital Line Circuit Pack.
2313
ABORT
The Maintenance/Test digital port allocated for this test did not respond to 
downlinked message.
1. Look for M/T-DIG errors in the Error Log. If present, refer to "M/T-DIG 
(Maintenance/Test Digital Port)" section.
2. Retry the command at 1-minute intervals a maximum of 5 times.
3. If the test continues to abort, replace the MTB.
2314
ABORT
Data Module did not respond to downlinked message.
1. Check the wiring of the Data Module under test.
2. Verify that the Data Module is powered (power LED on).
3. Make sure the switches are on NORM, OFF (between REM_LP and LOC_
LP), 9600, and ASYN.
4. If the test still aborts, replace the Date Module.
5. If the same abort code appears, replace the Digital Line Circuit Pack which 
is connect to the Data Module.
Table 9-467.
TEST #175 Data Module Internal LoopAround Test  — Continued
Error 
Code
Test 
Result
Description/ Recommendation