DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-1177
PE-BCHL (PRI Endpoint Port) 
9
PE-BCHL (PRI Endpoint Port)
A PRI Endpoint provides ISDN-PRI (Primary Rate Interface) connections 
application equipment or terminal adapters that terminate ISDN-PRI. The 
equipment or terminal adapters are connected to the switch via the TN464C/D 
UDS1 interface circuit pack. This maintenance object monitors the PRI endpoint 
port hardware on the UDS1 circuit pack by logging hardware errors, running 
tests for port initialization, and running periodic and scheduled maintenance and 
demand tests.
Wideband Switching
Wideband switching supports end-to-end connectivity between customer 
endpoints at data rates from 128 to 1536 kbps over T1 facilities and to 1984 kbps 
over E1 facilities. DEFINITY switching capabilities are extended to support 
wideband calls comprised of multiple DS0s that are switched end-to-end as a 
single entity.
Wideband switching is designed for ISDN application equipment such as ISDN 
video codecs, but can also interface to non-ISDN application equipment by 
using PRI terminal adapters. In the same sense that a DEFINITY data module 
acts as a DCP or BRI terminal adapter between endpoint data such as V.35 and 
dialing interfaces such as RS-366 and a DCP interface, a PRI terminal adapter 
acts as a wideband terminal adapter between endpoint data and dialing 
interfaces and DEFINITY’s line-side ISDN PRI interface. Wideband switching 
introduces PRI endpoints on DEFINITY line-side interfaces.
A PRI endpoint has a unique extension number and consists of one or more 
contiguous B-channels on a line-side T1 or E1 ISDN PRI facility. Endpoints initiate 
and receive calls via ISDN SETUP messages indicating the data rate and 
specific B-Channels to be used, and communicate all other call status 
information via standard ISDN messages. Any DEFINITY ISDN signaling set such 
as Lucent, CCITT, or ECMA may be used for a line-side ISDN PRI facility.
Multiple PRI endpoints on one line-side facility are separate and distinct within 
the facility. Non-overlapping contiguous sets of B-Channels are associated with 
each PRI endpoint, and the endpoint equipment is expected to initiate calls 
within these boundaries. The endpoint application equipment must:
MO Name (in 
Alarm Log)
Alarm 
Level
Initial Command to 
Run
1
1.
For additional repair information, see also UDS1-BD and 
Chapter 5, ‘‘Alarms, Errors, and Troubleshooting’’
.
Full Name of MO
PE-BCHL
1
MINOR
test port 
UUCSSpp l
PRI Endpoint Port
PE-BCHL
WARNING
test port 
UUCSSpp sh
PRI Endpoint Port