Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-1198
PGATE-BD (Packet Gateway Circuit Pack) 
9
An Invalid LAPD frame error occurs if the frame contains bad CRC, is 
greater than the maximum length, or violates the link level protocol.
When invalid LAPD frame errors are reported, the ‘‘Invalid LAPD Frame 
Error Counter Test’’ should be executed to determine if the condition has 
cleared. When bus parity errors are reported, the ‘‘LANBIC Receive Parity 
Error Counter Test’’ should be performed to determine if the condition has 
cleared. Execution of the Packet Interface Test should be performed if this 
problem persists to verify the integrity of the circuit pack. If the Packet 
Interface Test passes, then the repair procedure for the packet bus should 
be consulted.
m. These errors occur when the Packet Gateway reports that it is congested 
or the ‘‘Congestion Query Test’’ fails. A Packet Gateway enters a 
congested state when the number of utilized buffers on the board exceeds 
a specified threshold.
The error types associated with congestion are defined as follows:
See description of ‘‘Congestion Query Test’’ for correct repair procedure to 
follow.
n. This error is reported when the call control signaling link fails or when the 
Link Status Test fails for an X.25 Packet Gateway circuit pack. The call 
control signaling link is considered failed when it is disconnected at the 
link level and cannot be reconnected quickly. If the link cannot be 
reconnected quickly, a MINOR off-board alarm is raised against the circuit 
pack. This failure may be due to circuit pack problems, packet bus 
problems, or packet interface circuit pack problems.
o. A critical failure has been detected in the Packet Bus interface of the 
circuit pack. The switch resets the circuit pack upon the report of one of 
these errors. If two of these errors are received in 15 minutes, a MINOR 
alarm is raised on the circuit pack. Try clearing the alarm by executing the 
reset board UUCSS command. The circuit pack should be replaced if this 
alarm cannot be resolved.
p. The circuit pack is hyperactive (flooding the switch with messages sent 
over the control channel) and is taken out of service when a threshold 
number of these errors are reported to the switch. It may exhibit one or 
more of the following symptoms:
1. Tests run on the ports of this circuit pack return NO-BOARD.
2305:
Invalid LAPD frame received
2306:
Parity error detected on received frame
2817:
Utilized buffers have exceeded high buffer mark
2819:
All buffers exhausted