Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-1200
PGATE-BD (Packet Gateway Circuit Pack) 
9
When it begins to affect service, error type 3843 escalates to error type 
1296.
s. This error is reported when the receive buffers for the packet interface 
overflow. Frequent occurrence of this error may be indicative of a 
congested circuit pack. See description of ‘‘Receive FIFO Overflow Error 
Counter Test.’’
System Technician-Demanded Tests: Descriptions 
and Error Codes
When inspecting errors in the system and deciding which ones to address, 
always investigate errors in the order they are presented in the table below.
Circuit Pack Restart Test (#252)
This destructive test is used to reset the circuit pack. This test is not part of either 
short or long demand test sequence and is executed only on detection of PPCPU 
errors. The circuit pack is reset via the SAKI Sanity Test (#53).
Control Channel Loop-Around Test (#52)
This test queries the circuit pack for its circuit pack code and vintage and verifies 
its records.
This test is non-destructive.
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence
D/ND
1
1.
D = Destructive; ND = Nondestructive
Control Channel Loop-Around Test #52
X
X
ND
Invalid LAPD Frame Error Counter Test #597
X
ND
LANBIC Receive Parity Error Counter Test #595
X
ND
Receive FIFO Overflow Error Counter Test #596
X
ND
Packet Interface Test #598
X
X
ND
Congestion Query Test #600
X
X
ND
Link Status Test #601
X
X
ND