Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-1235
PKT-BUS (Packet Bus) 
9
PKT-BUS (Packet Bus)
The packet bus consists of a single bus, and one such bus appears in each 
port-network. The packet bus in each port-network is physically independent 
from those in other port-networks, so each port-network has a separate PKT-BUS 
maintenance object. This bus supports the following types of connections:
Logical control links between the SPE and all Expansion Port-Networks 
(EPN)
ISDN-BRI D-channel transport (signaling)
ASAI D-channel transport (signaling)
ISDN-PRI D-channel (signaling)
X.25 system adjunct signaling and traffic
System Access Ports
The TN1655 Packet Interface circuit pack provides the SPE interface to the 
packet bus. Packet Bus testing depends on the TN771D Maintenance/Test circuit 
pack, the TN1655 Packet Interface circuit pack, TN570 Expansion Interface 
circuit pack, and the Packet port circuit packs (TN556 ISDN-BRI Line, TN553 
Packet Data Line, TN464 Universal DS1, and TN577 Packet Gateway). Packet 
Bus tests may abort if some of these are not present in the system. The tests may 
yield inconsistent results if any of this hardware is defective. The individual test 
descriptions provide more information.
The interactions between the packet bus and the circuit packs that use the bus 
are complex. Circuit pack failures can alarm the packet bus, while Packet Bus 
faults can alarm or interrupt service to one or more circuit packs and their ports 
and endpoints. The 
 section in 
Chapter 5, 
‘‘Alarms, Errors, and Troubleshooting’’
 describes Packet Bus maintenance and 
interactions circuit packs. That section should be referenced for all 
troubleshooting and repairs. The flowchart is the normal starting point for 
experienced technicians. Technicians unfamiliar with the packet bus and its 
implementation in R
Xr should study the introductory material (for example, 
‘‘What 
is the Packet Bus?’’
) before using the flowchart to diagnose and repair packet 
bus faults.
MO Name (in 
Alarm Log)
Alarm Level
Initial Command to Run
1
1.
where P is the port-network number indicated in the PORT field from the Alarm or Error Log.
Full Name of MO
PKT-BUS
MAJOR
test pkt P l r 2
1
Packet Bus
PKT-BUS
MINOR
test pkt P l
Packet Bus
PKT-BUS
WARNING
test pkt P l
Packet Bus