Maintenance Object Repair Procedures 
9-1237
PKT-BUS (Packet Bus) 
9
Hardware Error Log Entries and Test to Clear 
Value
Notes:
a. Within the last minute, packet circuit packs have reported errors that 
indicate a possible packet bus failure. The Aux Data value is 1 or 2, 
indicating that only one or more than one Packet circuit pack 
(respectively) have reported a possible packet bus failure.
b. The Maintenance/Test packet bus port (M/T-PKT) for this port-network has 
determined that there are more packet bus faults than the port can 
correct. The Aux Data value indicates the number of faulty leads.
c. Packet circuit packs have detected possible packet bus failures via in-line 
error or via background test failure. Examine the Error and Alarm logs for 
more specific PKT-BUS errors.
Table 9-494.
PKT-BUS Error Log Entries
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
1
1.
ON-BOARD indicates a problem with the packet bus itself.
Test to Clear Value
0
2
2.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate 
test description and follow the recommended procedures.
0
Any
Any
Any
test pkt port-network
1 (a)
1-2
Packet Circuit Pack 
Audit Test (#570)
MAJOR
ON
test pkt port-network P l r 2
513 (b)
1-24
Maintenance/Test 
Circuit Pack Query 
Test (#572)
MAJOR
ON
test pkt port-network P l r 2
1793 (c)
Any
None
2049 (d)
1-3
Maintenance/Test 
Circuit Pack Query 
Test (#572)
MINOR
ON
test pkt port-network P l r 2
2305 (e)
1-24
Maintenance/Test 
Circuit Pack Query 
Test (#572)
test pkt port-network P l
3329 (f)
1-7
none
WARNING
ON
test pkt port-network P l 
3585 (g)
Any
none
MINOR
ON
test pkt port-network P l 
3841 (h)
Any
none
MINOR
OFF
Continued on next page