Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-1281
PMS-LINK (Property Management System Link) 
9
PMS-LINK (Property Management 
System Link)
Property Management System (PMS) is a stand-alone computer system that 
environments such as hotels or hospitals use for services such as reservations, 
registration, messaging, housekeeping, night audit, billing, and inventory. The 
PMS Link provides a communications channel between the switch and the 
customer-owned PMS so that the PMS can interrogate the system for information 
related to the following features:
Message Waiting Notification
Controlled Restriction
Housekeeping Status
Check-in/Check-out
Room Change/Room Swap
Refer to 
DEFINITY Communications System Generic 3 Feature Description, 
555-230-204, for details of the PMS feature. The PMS device connects to the 
system via a data module (PDM, MPDM, DTDM) connected to a port on a TN754 
Digital Line circuit pack which is administered as a data extension. A PMS device 
can also be connected through an ADU to a port on TN726B. The PMS link to the 
processor is via a system port. A system port is comprised of a port on the 
TN726B Data Line circuit pack and a port on the TN553 Packet Data circuit pack 
connected to each other in a null-modem fashion. Refer to the PDATA-PT section 
for information on the system port connectivity.
PMS Link maintenance provides a strategy for maintaining the link between the 
switch and a PMS device. The strategy includes a set of tests for periodic 
diagnosis, detection of errors during normal operation, actions for 
troubleshooting, and raising alarms for serious problems. PMS Link Maintenance 
uses a ‘‘try-and-wait’’ mechanism for maintaining the PMS Link. If a PMS Link is 
torn down due to an error, PMS Link Maintenance attempts to bring up the link 
immediately. If the Link Setup fails, PMS Link Maintenance will wait for five 
minutes before the next retry. If the number of retries reaches a threshold (12), a 
Minor alarm is raised for service attention.
PMS Link Maintenance does not cover the maintenance of the elements 
composing the PMS physical link (the external PMS device, Data Module 
(PDM/MPDM/DTDM), Digital Line Port of a TN754 Digital Line circuit pack, ADU, 
or Data Line Port of TN726B Data Line circuit pack). If PMS Link Maintenance 
MO Name (in 
Alarm Log)
Alarm Level
Initial Command to 
Run
Full Name of MO
PMS-LINK
MINOR
test pms l
PMS Link
PMS-LINK
WARNING
test pms
PMS Link