Maintenance Object Repair Procedures 
9-1283
PMS-LINK (Property Management System Link) 
9
Hardware Error Log Entries and Test to Clear 
Values
Notes:
a. The PMS Link has been busied out with the busyout pms-link command. 
The link is torn down. Enter the release pms-link command to restore the 
link.
b. The Link Retry Test (#215) fails. An error was detected when setting up the 
link. Refer to the 
c. The PMS physical link is down for one of the following reasons:
Cable to the PMS device is disconnected.
Table 9-504.
PMS Link Maintenance Error Log Entries
Error 
Type
Aux Data
Associated Test
Alarm Level
On/Off 
Board
Test to Clear Value
0
1
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate
test description and follow the recommended procedures.
0
Any
Any
Any
test pms sh r 1
18 (a)
0
busyout pms-link
WARNING
OFF
release pms-link
257 (b)
Any
Link Retry Test 
(#215)
MINOR/
2
 
WARNING
2.
Minor alarms on this MO may be downgraded to Warning alarms based on the value used in the set
options
 command.
OFF
test pms-link l
513 (c)
Any
None
test pms-link
769 (d)
Any
None
1025 (e)
40-49
None
1281 (f)
10-19
None
1537 (g)
N0-N9
None
1793 (h)
Any
None
test pms-link
2049 (i)
Any
None
2305 (j)
50-59
None
release pms-link or test 
pms-link
2561 (k)
Any
None
test pms-link
2817 (l)
100-109 
200-209 
300-309
None
3073 (m)
70-79
None
3841 (n)