Lucent Technologies Release 7 User Manual
DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-1283
PMS-LINK (Property Management System Link)
9
Hardware Error Log Entries and Test to Clear
Values
Values
Notes:
a. The PMS Link has been busied out with the busyout pms-link command.
The link is torn down. Enter the release pms-link command to restore the
link.
link.
b. The Link Retry Test (#215) fails. An error was detected when setting up the
c. The PMS physical link is down for one of the following reasons:
■
Cable to the PMS device is disconnected.
Table 9-504.
PMS Link Maintenance Error Log Entries
Error
Type
Aux Data
Associated Test
Alarm Level
On/Off
Board
Test to Clear Value
0
1
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate
test description and follow the recommended procedures.
test description and follow the recommended procedures.
0
Any
Any
Any
test pms sh r 1
18 (a)
0
busyout pms-link
WARNING
OFF
release pms-link
257 (b)
Any
Link Retry Test
(#215)
(#215)
MINOR/
2
WARNING
2.
Minor alarms on this MO may be downgraded to Warning alarms based on the value used in the set
options command.
options command.
OFF
test pms-link l
513 (c)
Any
None
test pms-link
769 (d)
Any
None
1025 (e)
40-49
None
1281 (f)
10-19
None
1537 (g)
N0-N9
None
1793 (h)
Any
None
test pms-link
2049 (i)
Any
None
2305 (j)
50-59
None
release pms-link or test
pms-link
pms-link
2561 (k)
Any
None
test pms-link
2817 (l)
100-109
200-209
300-309
200-209
300-309
None
3073 (m)
70-79
None
3841 (n)
20-29
None