Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-1294
PNC-DUP (PNC Duplication) 
9
PNC-DUP (PNC Duplication)
In systems with the Critical Reliability option, the following components, which 
together comprise the Port Network Connectivity (PNC), are duplicated:
Expansion Interface (EI) TN570 circuit packs in the port networks (PNs)
Switch Node Interface (SNI) TN573 circuit packs in switch nodes
DS1 Converter (DS1C) TN574 circuit packs for remote EPN connections
Fiber-optic cables (metallic in certain cases) connecting the above circuit 
packs
DS1 facilities between the DS1Cs
Switch Node Clock (SNC) TN572 circuit packs
Although not part of the PNC, Tone-Clock circuit packs are also duplicated in 
each PN. The PNC is available in two different configurations: direct connect, in 
which each port network is connected directly by fiber optic links to each other 
PN; and Center Stage Switch (CSS) which utilizes one or two switch nodes to 
interconnect the PNs. All systems have one Processor Port Network (PPN). Direct 
connect systems can have up to two Expansion Port Networks (EPNs). CSS 
systems with one switch node can have up to 15 EPNS. CSS systems with two 
switch node can have up to 21 EPNS. See the following figures.
PNC duplication architecture utilizes an active/standby duplication scheme, in 
which one complete set of PNC components supports call processing, while the 
duplicate PNC is held in reserve. All calls on the active PNC are simultaneously 
set up, or shadowed, on the standby PNC in order for it to be capable of instantly 
assuming active status when necessary, allowing for interchanges without 
service disruption (in the case of single faults).
The PNC-DUP maintenance object tracks the health of the active and standby 
PNCs, controls planned and spontaneous interchanges, and manages related 
functions such as double call refresh and unrefresh, antithrashing, and so on. 
The main responsibility of PNC-DUP is to recover the system to full service in the 
event of a fault. In the event of multiple faults PNC-DUP will do its best to 
maximize service continuity.
PNC duplication does not introduce any additional types of hardware or 
hardware faults, and there are no tests associated with the PNC-DUP MO. 
Instead, it’s error log entries are used to log useful information about the 
occurrence and causes of interchanges in order to facilitate diagnosis of 
problems which can then be addressed by using the documentation for the 
individual maintenance object involved.
MO Name (in 
Alarm Log)
Alarm 
Level
Initial Command to 
Run
Full Name of MO
PNC-DUP
NA
status pnc