Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-1314
POWER 
9
NOTE:
If any defective batteries are found, replace all of them. Batteries are 
ordered in sets of three and should be replaced as such.
6. If no defective batteries are found, replace the entire charger.
7. Close the cover and secure it with the screw.
8. Reconnect the cord and move the power switch to ON.
Replacing the Battery Assembly (J58890CH)
The batteries are replaced as an entire assembly.
1. Check the battery voltages at the test points (on the Battery Interface Unit 
(BIU)).
2. Remove the BIU from the power distribution unit.
3. Disconnect the battery plug from the power distribution unit (J20).
4. Remove the battery assembly from the rear of the cabinet.
5. Install the new battery assembly in the reverse order.
6. Plug the BIU back into the power distribution unit.
Error Log Entries and Test to Clear Values
Table 9-511. Battery & Battery Charger Error Log Entries 
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
0
1
0
Any
Any
Any
test environment 
UU sh r 1
1
Any
Battery & Battery 
Charger Query Test 
(#5) (error code 8)
MINOR
ON
test environment 
UU s r 1
257
Any
Battery & Battery 
Charger Query Test 
(#5) (error code 4)
MINOR
ON
test environment 
UU s r 1
769
Any
Battery & Battery 
Charger Query Test 
(#5) (error code 2)
MINOR
ON
test environment 
UU s r 1