Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-1325
PPP-PT (Control LAN Packet/Port) 
9
PPP-PT (Control LAN Packet/Port)
The TN799 Control LAN (CLAN) packet port circuit pack provides TCP/IP 
connection to adjuncts applications such as CMS, Intuity, and DCS Networking. 
The CLAN circuit pack has 1-10baseT Ethernet connection and up to 16 DS0 
physical interfaces for PPP connections. Two integrated modems provide remote 
PPP connectivity over analog facilities. Multiple CLAN circuit packs (maximum 2 
per system) in a system gives additional TCP/IP capacity.
A remote socket control link (RSCL) links the CLAN and the SPE to pass call 
control and other management information. Since one link serves all the ports on 
the circuit pack, maintenance of the RSCL is part of the CLAN circuit pack 
maintenance.
NOTE:
The CLAN TN799 circuit pack combines the functions of the PGATE and PI 
circuit packs into one circuit pack. The PGATE or PI can be used with the 
CLAN to create an X.25 to TCP/IP bridge for adjunct and DCS connectivity.
Control LAN Congestion Controls
The switch activates congestion controls on CLAN when it detects buffers 
exceeding the threshold. The switch releases the congestion controls when the 
CLAN reports that its buffer level has returned to normal levels.
MO Name (in 
Alarm Log)
Alarm Level
Initial Command to Run
1
1.
UU is the universal cabinet number (1 for PPN, 2 - 44 for EPNs). C is the carrier designation (A, B, 
C, D, or E). 
SS is the number of the slot in which the circuit pack resides (01 to 21). pp is the two 
digit port number (01, 02, ...).
Full Name of MO
PPP-PT
MAJOR
test port UUCSSpp long
PPP Port Maintenance
PPP-PT
MINOR
test port UUCSSpp long
PPP Port Maintenance
PPP-PT
WARNING
test port UUCSSpp
PPP Port Maintenance
If congestion:
Then the switch:
Persists for a 14-minute interval
Raises MINOR alarm
Exhausts buffers
Raises MINOR alarm
Ceases for 12 minutes
Retires MINOR alarm