Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-1327
PPP-PT (Control LAN Packet/Port) 
9
procedures to verify repair.
3. Clear the alarm (test port UUCSSpp long clear).
c. Error Type 513: PPP link lost end-to-end connectivity.
1. Test for hardware problem (test port UUCSSpp long).
2. Run TDM Looparound Test (#1285) and refer to repair procedures if 
there is a hardware problem.
If there is no hardware problem, the switch tries to re-establish PPP 
link.
d. Error Type 769: Port received an invalid frame, which
is greater than the maximum length
contains CRC errors
violates the link level protocol.
1. Test the port (test port UUCSSpp long).
3. Clear the alarm (test port UUCSSpp long clear).
e. Error Type 1281: System software received an indication that the far-end 
has requested a disconnect of a session on this link. This is a log-only 
error.
f. Error Type 1537, 1538: Some or all port sessions (sockets) are down. 
g. Error Type 1793-1920: system software received an indication that a 
socket was closed due to an error. Error Type indicates the application f 
the application associated with this socket.
Aux Data indicates the internal application number.
h. Error Type 2305-2816: System software detected a session is down. Aux 
Data indicates the session number.
If the switch indicates that:
Then it:
Some of the sessions are down
Raises off-board WARNING
All of the sessions are down
Raises off-board MINOR alarm
Error Type
Application
1794
DCS
1795
AUDIX
1796
CMS
1797
ISDN Gateway