Lucent Technologies Release 7 User Manual
DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-1328
PPP-PT (Control LAN Packet/Port)
9
i. Error Type 3329: TCP/IP Ping Test failed.
j. Error Type 3585: TDM Port Looparound Test (#1285) failed.
1. Test the port (test port UUCsspp long).
2. Refer to
‘‘TDM Looparound Test (#1285)’’
repair procedure.
System Technician-Demanded Tests: Descriptions
and Error Codes
and Error Codes
Investigate errors in the order they appear in the table below.
TDM Looparound Test (#1285)
This test is destructive.
This test verifies whether the CLAN PPP port can send and receive data on the
TDM bus. This test has a tone generator send tones on a timeslot, and it has a
TDM bus. This test has a tone generator send tones on a timeslot, and it has a
If the switch:
Then it:
Exceeds threshold failure rate
Raises off-board WARNING alarm on
circuit pack
circuit pack
Table 9-517.
System Technician-Demanded Tests: CLAN-PT
Order of Investigation
Short Test
Sequence
Long Test
Sequence
Sequence
D/ND
1
1.
D = Destructive, ND = Non-destructive
TDM Looparound Test (#1285)
X
D
SCOTCH Synchronous Looparound Test (#1275)
X
D
TCP/IP Ping Test (#1281)
X
X
ND
Session Status Test (#1286)
X
X
ND
PPP Link Status Test (#1279)
X
X
ND
Continued on next page