Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-1362
S-SYN-PT (Speech Synthesis Port) 
9
Error Log Entries and Test to Clear Values
Notes:
a. An in-line failure of the on-board microprocessor/PSS handshake has 
occurred. Refer to Test #168 for repair procedures.
b. This error type indicates that the circuit pack been removed or has been 
insane for more than 11-minutes. To clear the error, reinsert or replace the 
circuit pack.
Table 9-538.
Speech Synthesis Port Error Log Entries
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
0
1
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate
test description and follow the recommended procedures.
0
Any
Any
Any
test port UUCSSpp sh r 1
1(a)
17672
None
18
0
busy-out port 
UUCSSpp
WARNING
OFF
release port UUCSSpp
130(b)
None
WARNING
ON
test port UUCSSpp sh
257
Speech Synthesis PSS 
Handshake Test (#168)
MAJOR
ON
test port UUCSSpp sh r 2
513
17922
Speech Synthesis 
Memory Test (#166)
MINOR
ON
test port UUCSSpp sh r 2
769
17664
Speech Synthesis 
DTMF Receiver Inquiry 
Test (#164)
MINOR
ON
test port UUCSSpp sh r 2
1025
17670
Speech Synthesis SSD 
Inquiry Test (#167)
MINOR
ON
test port UUCSSpp sh r 2
1281
Speech Synthesis DSP 
Tone Test (#165)
MINOR
ON
test port UUCSSpp sh r 2
1537
Speech Synthesis 
Memory Test (#166)
MINOR
ON
test port UUCSSpp sh r 2
1793
Speech Synthesis 
DTMF Receiver Test 
(#163)
MINOR
ON
test port UUCSSpp l r 2
2049(c)
Conference Circuit Test 
(#7)
MINOR
ON
test port UUCSSpp l r 2
2305
NPE Crosstalk Test (#6)
MINOR
ON
test port UUCSSpp l r 2
3840(d)
Any
None