Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-1363
S-SYN-PT (Speech Synthesis Port) 
9
c. A transient error that does not cause an alarm can occasionally occur 
during a SPE, TDM BUS, or Tone Clock interchange. Test the port and 
follow the instructions for conference Test (#7).
d. This error is not service-affecting and no action is required.
System Technician-Demanded Tests: Descriptions 
and Error Codes
Always investigate tests in the order presented in the table below when 
inspecting errors in the system. By clearing error codes associated with the 
NPE 
Crosstalk Test, for example, you may also clear errors generated from other tests 
in the testing sequence.
NPE Crosstalk Test (#6)
The NPE Crosstalk Test verifies that this port’s NPE channel talks on the selected 
time slot and never crosses over to time slots reserved for other connections. If 
the NPE is not working correctly, one-way and noisy connections may occur. This 
test is usually only part of a port’s Long Test Sequence and takes about 20 to 30 
seconds to complete.
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence
D/ND
1
1.
D = Destructive, ND = Non-destructive
Speech Synthesis PSS Handshake Test (#168)
X
X
ND
NPE Crosstalk Test (#6)
X
ND
Conference Circuit Test (#7)
X
ND
Speech Synthesis DTMF Receiver Test (#163)
X
ND
Speech Synthesis Memory Test (#166)
X
X
ND
Speech Synthesis DSP Tone Test (#165)
X
X
ND
Speech Synthesis SSD Inquiry Test (#167)
X
X
ND
Speech Synthesis DTMF Receiver Inquiry Test (#164)
X
X
ND
Speech Synthesis Parameter Update Test (#169)
X
X
ND