Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-1424
SNC-REF (Switch Node Clock Reference) 
9
Error Log Entries and Test to Clear Value
Notes:
a. This error occurs whenever the active or standby SNC detects problems in 
its timing reference with an SNI circuit pack in the same carrier. The slot 
location of the SNI with which the SNC cannot communicate is given in the 
error table above.
If duplicated SNCs exist in the carrier: 
1. If the SNCs are duplicated in the carrier, check the error log via 
display errors. If both SNCs have this error, replace the SNI that 
the SNCs are complaining about.
Table 9-557.
SNC Reference Error Log Entries
Error 
Type
Aux 
Data
SNI 
Slot
1
1.
The slot location of the SNI with which the SNC cannot communicate.
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
0
2
2.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate
test description and follow the recommended procedures.
0
Any
Any
Any
test board UUCSS r 1
1(a)
Any
2
Failure Audit (#777)
MAJOR
OFF
test board UUCSS r 1
257(a)
Any
3
Failure Audit (#777)
MAJOR
OFF
test board UUCSS r 1
513(a)
Any
4
Failure Audit (#777)
MAJOR
OFF
test board UUCSS r 1
769(a)
Any
5
Failure Audit (#777)
MAJOR
OFF
test board UUCSS r 1
1025(a)
Any
6
Failure Audit (#777)
MAJOR
OFF
test board UUCSS r 1
1281(a)
Any
7
Failure Audit (#777)
MAJOR
OFF
test board UUCSS r 1
1537(a)
Any
8
Failure Audit (#777)
MAJOR
OFF
test board UUCSS r 1
1793(a)
Any
9
Failure Audit (#777)
MAJOR
OFF
test board UUCSS r 1
2049(a)
Any
13
Failure Audit (#777)
MAJOR
OFF
test board UUCSS r 1
2305(a)
Any
14
Failure Audit (#777)
MAJOR
OFF
test board UUCSS r 1
2561(a)
Any
15
Failure Audit (#777)
MAJOR
OFF
test board UUCSS r 1
2817(a)
Any
16
Failure Audit (#777)
MAJOR
OFF
test board UUCSS r 1
3073(a)
Any
17
Failure Audit (#777)
MAJOR
OFF
test board UUCSS r 1
3329(a)
Any
18
Failure Audit (#777)
MAJOR
OFF
test board UUCSS r 1
3585(a)
Any
19
Failure Audit (#777)
MAJOR
OFF
test board UUCSS r 1
3841(a)
Any
20
Failure Audit (#777)
MAJOR
OFF
test board UUCSS r 1