SPE-SELE (SPE Select Switch)
9
SPE-SELE (SPE Select Switch)
The SPE Select Switch MO monitors the position of the SPE Select switches
located on the front of each UN330B Duplication Interface board. Each switch
may be in one of three possible positions: Auto, A selected, B selected. Both
switches, one on the active Duplication Interface board and one on the standby,
should be set to the same designation. The switches control selection of the
active SPE and cause alarms as follows:
located on the front of each UN330B Duplication Interface board. Each switch
may be in one of three possible positions: Auto, A selected, B selected. Both
switches, one on the active Duplication Interface board and one on the standby,
should be set to the same designation. The switches control selection of the
active SPE and cause alarms as follows:
■
If both switches are in the AUTO position, the SPE that is the healthiest, as
determined by the state-of-health bits on the boards, is selected as active.
No alarm is raised.
determined by the state-of-health bits on the boards, is selected as active.
No alarm is raised.
■
If one SPE Select switch is in the AUTO position and one selecting either A
or B carrier as active, or one switch selects A and the other selects B, the
boards default to handling the selection of which carrier is active as if both
switches were in the AUTO position. A WARNING alarm appears after one
hour. The alarm is resolved 5 minutes after the switches are returned to
identical positions.
or B carrier as active, or one switch selects A and the other selects B, the
boards default to handling the selection of which carrier is active as if both
switches were in the AUTO position. A WARNING alarm appears after one
hour. The alarm is resolved 5 minutes after the switches are returned to
identical positions.
■
If both switches select either A carrier or B carrier active, then the
Duplication Interface boards will force that carrier active (irrespective of
state-of-health) and the red Override LED is lit. A MAJOR alarm is raised
by SPE-SELE if the switches remain in these positions for more than 6
hours. The alarm is resolved within 5 minutes of the switches being
returned to AUTO.
Duplication Interface boards will force that carrier active (irrespective of
state-of-health) and the red Override LED is lit. A MAJOR alarm is raised
by SPE-SELE if the switches remain in these positions for more than 6
hours. The alarm is resolved within 5 minutes of the switches being
returned to AUTO.
MO Name (in
Alarm Log)
Alarm
Level
Initial Command to Run
Full Name of MO
SPE-SELE
MAJOR
none
SPE Select Switch
SPE-SELE
WARNING
none
SPE Select Switch