DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-1492
SPE-SELE (SPE Select Switch) 
9
Figure 9-88.
Duplication Interface Circuit Pack
Error Log Entries and Test to Clear Values
Notes:
a. Error 1 appears when one SPE Select Switch is in the AUTO position and 
the other is in the select A or select B position. Placing both switches in 
the AUTO position will retire the alarm immediately.
b. Error 257 appears when both SPE Select Switches are in the select A or 
select B position for more that 6 hours. Placing both switches in the AUTO 
position will retire the alarm immediately.
Table 9-568.
SPE Select Switch Error Log Entries
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
0
1
1.
Check the position of the SPE-Select switches.
0
Any
Any
Any
1(a)
0
none
WARNING
OFF
257(b)
0
none
MAJOR
OFF
SPE-Select Switch
SPE-Select LED (Red)
Alarm LED (Red)
Test LED (Green)
Busy LED (Yellow)
O
O
O
SPE
AUTO
Override
A
O
O