Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-1515
STO-DATA (Stored Data) 
9
STO-DATA (Stored Data)
NOTE:
STO-DATA problems can be caused by faulty MSS hardware or hardware 
used to provide communication between active and standby SPEs. If 
hardware errors are present for H-ADAPTER, TAPE, DISK, or DUPINT, 
investigate those first and then run test stored-data to address file 
inconsistencies.
The Mass Storage System (MSS) consists of the following components which are 
part of the system’s SPE:
TN1656 Disk circuit pack
TN1656 Tape circuit pack
Host Adapter circuit located on the UN332 MSS/Network Control circuit 
pack
Each disk and tape drive stores 2 copies of each of the following:
The software that the system runs (the ‘‘boot image’’) 
Translation data
Software update data (also known as program updates or patches)
Announcement files from the TN750 Announcement circuit pack
File directory
Error log
In special circumstances, a core dump of all system memory (single copy)
The disk is the primary storage device. Files on disk are generally used to reboot 
the system or to restore files that are lost or corrupted during a malfunction. The 
tape is used to backup the disk and as a portable medium for data, such as is 
used for introduction of a new software load.
In High and Critical Reliability systems (duplicated SPE) the tape and disk drives 
are duplicated as part of the PPN control carrier, resulting in a total of 4 devices, 
each storing 2 copies of the aforementioned files. Ideally, the files on all of the 
devices are identical, but malfunctions or even normal operations can lead to 
inconsistencies.
MO Name (in 
Alarm Log)
Alarm Level
Initial Command to Run
Full Name of MO
STO-DATA
MINOR
test stored-data [long]*
Stored Data
STO-DATA
WARNING
test stored-data
Stored Data