Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-1516
STO-DATA (Stored Data) 
9
Data Inconsistencies and STO_DATA Tests
The STO-DATA maintenance object is not a hardware component, but a strategy 
used to test for consistency between corresponding files on the different storage 
devices. When inconsistencies are found, STO-DATA errors and alarms are 
generated. The translation, announcement, and software update files are 
checked by comparing timestamps created when the files were saved from 
system memory. The boot image files are checked by comparing vintage 
numbers. The other files are not checked.
On systems with simplex SPE, a STO-DATA test compares the files on tape to 
those on the disk. On systems with duplicated SPEs, the following comparisons 
of corresponding files are made:
1. Disk to tape (active SPE)
2. Disk to tape (standby SPE)
3. Disk (active SPE) to disk (standby SPE)
4. Tape (active SPE) to tape (standby SPE)
The data consistency tests are run as part of the short and long demand test 
sequences and automatically during daily scheduled maintenance. Test results 
point to which files, if any, are out of date.
In addition to the data consistency tests, checksum tests are run during the long 
demand test sequence to verify that the checksums of both copies of the boot 
image on each storage device are the same. This capability is useful when the 
system has booted using a boot image other than the first copy on disk. (An 
alarm and unique error code identify this situation). In addition to test results, you 
can use the list configuration software command to retrieve detailed 
information about the files on each storage device.