Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-1521
STO-DATA (Stored Data) 
9
Error Log Entries and Test to Clear Values
Table 9-576.
STORED-DATA Error Log Entries 
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
1 (a)
1 to 6
Carrier A Tape-Disk 
Consistency Test (#833)
WARNING
OFF
test stored-data
257 (b)
1
Carrier A Tape-Disk 
Consistency Test (#833
WARNING
OFF
test stored-data
513 (a)
1 to 6
Carrier B Tape-Disk 
Consistency Test (#834)
WARNING
OFF
test stored-data
542 (c)
0
Scheduled translation save
-
-
543 (d)
0
Scheduled disk backup
-
-
769 (b)
1
Carrier B Tape-Disk 
Consistency Test (#834)
WARNING
OFF
test stored-data
1025 (e)
1 to 6
Tape-Tape Consistency 
Test (#835)
MINOR
OFF
 test stored-data
1281 (f)
1
Tape-Tape Consistency 
Test (#835)
MINOR
OFF
 test stored-data
1537 (e)
1 to 6
Disk-Disk Consistency Test 
(#836)
MINOR
OFF
 test stored-data
1793 (f)
1
Disk-Disk Consistency Test 
(#836)
MINOR
OFF
 test stored-data
2049 (g)
1 to 3
Carrier A Boot Image Test 
(#837) (Runs at system 
boot time only)
MINOR
OFF
 test stored-data long
2305 (g)
1 to 3
Carrier B Boot Image Test 
(#837) (Runs at system 
boot time only)
MINOR
OFF
 test stored-data long
2561 (h)
300043
001430
201
Carrier A Tape Checksum 
Test (#829)
MINOR
OFF
 test stored-data long
2817 (h)
300043
001430
201
Carrier A Disk Checksum 
Test (#830)
MINOR
OFF
 test stored-data long
3073 (h)
30004
30014
30201
Carrier B Tape Checksum 
Test (#831)
MINOR
OFF
 test stored-data long
Continued on next page