Lucent Technologies Release 7 User Manual
DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-1522
STO-DATA (Stored Data)
9
Notes:
a. Error types 1 and 513 indicate that one or more of the following conditions
has occurred on Carrier A or Carrier B respectively: the timestamps of the
translation files on the two storage devices are inconsistent, the
timestamps of the announcement files on the two storage devices are
inconsistent, or the timestamps of the program update files on the two
storage devices are inconsistent.
translation files on the two storage devices are inconsistent, the
timestamps of the announcement files on the two storage devices are
inconsistent, or the timestamps of the program update files on the two
storage devices are inconsistent.
The auxiliary data for the error type can be used to determine which files
are inconsistent. That information is presented in the table below. More
than one data inconsistency may exist, but only the fault with the highest
auxiliary data number will appear in the error log. Enter the test
stored-data command to obtain more information about the failure and
follow the associated repair procedures.
are inconsistent. That information is presented in the table below. More
than one data inconsistency may exist, but only the fault with the highest
auxiliary data number will appear in the error log. Enter the test
stored-data command to obtain more information about the failure and
follow the associated repair procedures.
3329 (h)
30004
30014
30201
30014
30201
Carrier B Disk Checksum
Test (#832)
Test (#832)
MINOR
OFF
test stored-data long
3585 (i)
Any
WARNING
OFF
test stored-data
3586 (j)
Any
WARNING
OFF
test stored-data
3587 (k)
Any
WARNING
OFF
test stored-data
3841 (i)
Any
WARNING
OFF
test stored-data
3842 (j)
Any
WARNING
OFF
test stored-data
3843 (k)
Any
WARNING
OFF
test stored-data
Table 9-577.
Auxiliary Data for Error Types 1 and 513
Aux
Data
Data File Inconsistency
1
Disk translation data is newer than the tape translation data
2
Tape translation data is newer than the disk translation data
3
Disk announcement data is newer than the tape announcement data
4
Tape announcement data is newer than the disk announcement data
5
Disk program update data is newer than the tape program update data
6
Tape program update data is newer than the disk program update data
Table 9-576.
STORED-DATA Error Log Entries — Continued
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
Continued on next page