Maintenance Object Repair Procedures 
9-1694
TBRI-TRK (TN2185 ISDN Trunk-Side BRI) 
9
System Technician-Demanded Tests: 
Descriptions and Error Codes
Always investigate tests in the order presented in the table below when 
inspecting errors in the system. By clearing error codes associated with the 
Services State Test, for example, you may also clear errors generated from other 
tests in the testing sequence.
Signaling Link State (#1251)
This test is non-destructive.
This test checks the current state of the signaling link. The test looks at the 
board-level translations, checks that the board is physically inserted, gets the 
state of the D-Channel and service state of the port. 
The test passes if the signaling link (D-Channel) is connected and operating 
normally. The test fails if the board is not installed, the signaling link is 
disconnected, or if the port is out of service. The test aborts otherwise.
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence
D/ND
1
1.
Destructive; ND = Nondestructive
Signaling Link State Check Test (#1251)
X
X
ND
Service State Audit Test (#256)
X
X
ND
Call State Audit Test (#257)
X
X
ND
ISDN Test Call Test (#258)
X
ND
Table 9-636.
TEST #1251 Signaling Link State Test 
Error 
Code
Test 
Result
Description/ Recommendation
ABORT
Internal system error
1018
ABORT
The test is disabled.
1. Enable the test by entering enable test #1251.
1114
ABORT
The signaling link is in a transitional state.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to abort, escalate the problem.
Continued on next page