Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-1696
TBRI-TRK (TN2185 ISDN Trunk-Side BRI) 
9
Call State Audit Test (#257)
This test is nondestructive.
This test performs a call state audit on an ISDN B-Channel, and upon successful 
completion, guarantees that both sides of the interface are in a consistent call 
state for connections using the B-Channel. The test can be helpful when trying to 
clear a hung call. If the internal call state data to the near-end switch is different 
from that of the far-end switch, the call will be torn down.
The test passes if the audit is successful.
1113
ABORT
The signaling link has failed, so the system cannot send any messages on 
behalf of this trunk.
1. Check the results of Test #1251 (Signaling Link State Test).
1114
ABORT
The signaling link is in a transitional state.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1116
ABORT
The trunk is not in a service state which is appropriate for running the test. 
This test is only performed in the OOS/FE state.
1117
ABORT
A service state audit message is outstanding.
1. Wait two minutes and then try again.
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
FAIL
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
PASS
Wait 4 minutes and then check the Error Log for any new errors of type 
3073. If there are none, then both sides of the ISDN connection agree on 
the service state; the negotiation succeeded. If there is a new 3073 error, 
then the negotiation failed (the far-end switch twice failed to respond within 
2 minutes). The switch automatically retries every 15 minutes. If the trunk 
was initially in-service, it is now placed in the maintenance/far-end state. 
Incoming calls are accepted, but no outgoing calls can be originated. If an 
incoming call is presented, another Service State Audit is immediately 
performed in an attempt to put the TN2185 ISDN Trunk-Side BRI Channel 
in the proper state.
Table 9-637.
TEST #256 Service State Audit Test  — Continued
Error 
Code
Test 
Result
Description/ Recommendation
Continued on next page