Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-1725
TDM-CLK (TDM Bus Clock) 
9
2. Refer to SYNC maintenance, in the “Approach to Troubleshooting” 
section, if the error is not resolved by step 1
Error Type 1282
Indicates that the TN2182 tone-clock was synchronized 
to a DS1 facility and that the reference frequency provided by the DS1 
drifted beyond a range that could be tracked by the TN2182. Therefore 
the TN2182 is no longer synchronized to that DS1 reference. If a second 
DS1 is available, the tone-clock may be synchronized to that reference. If 
no secondary DS1 reference is available, the tone-clock will run off of its 
internal clock. This may result in slips being reported by the tone-clock 
and all DS1 facilities.
i. The tone-clock circuit pack in the master port network was unable to 
detect the incoming synchronization signal, but the other tone-clock was 
able to detect the references. If the aux data is 0, the problem is with the 
signal on the primary. If the aux data is 1, the problem is with the signal on 
the secondary. The system should switch clocks in this situation. 
1. If this error is against a PPN clock board and the system is using a 
Stratum 3 clock, check the cabling that brings the stratum 3 signal 
to this clock board.
2. Replace the current standby Tone-Clock circuit pack. See 
j. The indicated active Tone-Clock circuit pack, which is on a port network 
that does not contain the system synchronization reference (a slave 
Tone-Clock), has detected a loss of timing signal from its EXP-INTF 
synchronization source.
1. Enter display errors and display alarms, and follow the 
associated repair procedures for EXP-INTF, TDM-CLK, and 
TONE-BD error log entries that have on-board alarms.
2. If the 2305 errors persist, follow the repair procedures for EXP-INTF 
error log entries 257, 769, or 770, or any errors logged against 
SNI-BD, SNC-BD, or FIBER-LK.
3. If the 2305 errors persist:
a.
For Port Networks with more than one Tone-Clock circuit 
pack, execute the command test synchronization r 10, and 
check to see if new 2305 errors against TDM-CLK were 
reported. If not, execute reset PNC interchange and then test 
synchronization r 10 again, and recheck for new 2305 errors 
against TDM-CLK
b.
For Port Networks with a single Tone-Clock circuit pack, 
execute the command test synchronization r 10, and check 
to see if new 2305 errors were reported.
If no new instances of the 2305 errors were logged for either test, 
then enter test tone-clock UUC long clear to clear the TDM-CLK 
errors and the procedure is complete.