Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-1807
TSC-ADM (Administered Temporary Signaling Connections) 
9
TSC-ADM (Administered Temporary
Signaling Connections) 
No alarms are generated for Administered Temporary Signaling Connections 
(TSC-ADM, also called ADM TSCs).
Administered temporary signaling connections provide a path through ISDN-PRI 
networks for supplementary D-channel messages. ISDN-PRI applications such 
as the Distributed Communications System (DCS) use temporary signaling 
connections to exchange user information across an ISDN-PRI network. What 
makes Administered TSCs unique is that these particular TSCs stay active for an 
extended period of time, similar to a permanent data connection. These ADM 
TSCs are used for DCS features that require Non-Call Associated (NCA) TSCs, 
and the ADM TSC provides the logical channel function in a DCS network.
An NCA TSC is a virtual connection established within a D-channel without 
associating any B-channel connections. The connection provides user-to-user 
service by exchanging USER INFORMATION messages without associated 
B-channel connections.
An Administered TSC is a special NCA TSC defined for the DCS over the 
ISDN-PRI D-channel. The ADM TSC has an administratively defined endpoint 
and is established for an extended period of time.
There are two types of ADM TSCs:
Permanent
These are established by the originating PBX (Near-end ADM TSC) or by 
the terminating PBX (Far-end ADM TSC). Once these ADM TSCs are 
established, they remain active.
As-Needed
These are established only when needed.
ADM TSC maintenance provides a strategy to verify that a far-end can respond 
to an ISDN-PRI USER INFORMATION TSC heartbeat message, thereby 
indicating that user-user signaling is functioning. In addition, maintenance can 
retrieve the status of the ADM TSC’s connection state.
Since ADM TSCs are administered on a per signaling group basis, the health of 
an ADM TSC also depends on the state of the D-channel or D-channel pair 
administered per signaling group. Refer to ISDN-SGR documentation for details 
on ISDN-PRI NFAS and D-channel Backup maintenance.
MO Name (in 
Alarm Log)
Alarm 
Level
Initial Command 
to Run
Full Name of MO
TSC-ADM
none
none
Administered Temporary Signaling Connections