Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-1808
TSC-ADM (Administered Temporary Signaling Connections) 
9
The two administration commands for ADM TSCs are as follows:
add signaling group number
change signaling group number
The two maintenance commands for ADM TSCs are as follows:
test tsc-administered signaling group number [/tsc index]
status tsc-administered signaling group number [/tsc index]
Error Log Entries and Test to Clear Values
Note:
a. There is no Test to Clear Value for error types 3840-3967. These error 
types provide the following additional data that may prove useful when 
tracking down problems.
Any of these errors indicates that a TSC Heartbeat Inquiry Test was run on 
an active far-end Administered TSC from the switch. Upon receiving the 
heartbeat message, the network communicated that the call was unable 
to complete. As a result, the error was logged. Check the signaling group 
status of the D-channel or D-channel pair via the status signaling-group 
<group>
 command for the Administered TSC. Check the status of the 
Administered TSC via the status tsc-administered command. Also check 
the administration of the Administered TSC on the switch.
This error may only be affecting service for some DCS customers. Upon 
receipt of this error condition, the switch will tear down and re-establish 
the ADM TSC within 20 minutes.
Table 9-675.
ADM TSC Error Log Entries
Error Type
Aux Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
3840-3967 (a)
tsc index #
test tsc-administered