9-1816
TTR-LEV (TTR Level) 
9
Error Log Entries and Test to Clear Values
!
WARNING:
The Alarm is upgraded to MAJOR if the Base Tone Generator is set to 12 
(France).
Notes:
a. Error code 1 does not indicate a current error condition. It indicates that 
the number of DTMR ports in service was below the administered 
threshold, but is now equal to or greater than the threshold. These errors 
are typically generated during boot time or other transitional states when 
the ports are being brought into service.
b. The total number of DTMR ports currently in service is below the 
administered threshold. To clear the alarm, refer to the repair procedure 
described above.
c. Error code 3 does not indicate a current error condition. It indicates that 
the number of GPTD ports in service was below the administered 
threshold, but is now equal to or greater than the threshold. These errors 
are typically generated during boot time or other transitional states when 
the ports are being brought into service.
d. The total number of GPTD ports currently in service is below the 
administered threshold. To clear the alarm, refer to the repair procedure 
describe above.
Table 9-677.
TTR Level Error Log Entries
Error 
Type
Aux 
Data
Associated Test
Alarm Level
On/Off 
Board
Test to Clear Value
1 (a)
1
None
2 (b)
2
WARNING
(See WARNING 
message below)
OFF
3 (c)
3
None
4 (d)
4
WARNING
OFF
5 (e)
5
None
6 (f)
6
WARNING
OFF
7 (g)
7
MAJOR
OFF
8 (h)
8
MINOR
OFF
9 (i)
9
MINOR
OFF