Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Additional Maintenance Procedures 
6-46
Automatic Transmission Measurement System (ATMS) 
6
ATMS Reports (List Testcall Command)
The list testcalls command produces detailed and summary reports of 
measurements made by the Automatic Transmission Measurement System 
(ATMS). Measurement reports contain data on trunk signal loss, noise, singing 
return loss, and echo return loss, and are used to determine the quality of trunk 
lines. The system maintains a database with the results of the last test for each 
trunk. System resets clear all transmission test data, and ATMS measurements 
are not backed up by the Mass Storage System.
ATMS parameters are administered on page 4 of the trunk group form. These 
include thresholds for marginal and unacceptable performance. On the screen 
display, measurements that exceed the marginal threshold are highlighted. 
Measurements that are exceed the unacceptable level appear flashing, 
indicating unusable trunks. Trunk groups can be administered to log errors and 
alarms, and busyout the failed trunk in response to such results.
The detailed report lists measurements for each trunk group member. The 
summary reports lists trunk groups as a whole. Which measurements are 
displayed depends on what type of test, if any, was last run on the trunk, and the 
capabilities of the TTL on the switch at the far end of the trunk. See the preceding 
description of the test analog-testcall command. A blank line indicates that no 
test data is available for that trunk or group.
The number of pages of each report is dependent upon the selection criteria and 
the number of outgoing trunks in the system. About 10 measurements can be 
listed on a page on the administration terminal, or about 50 measurements can 
be listed on a printer. By default, reports list all measurements. Filtering can be 
used to limit the output. For example, the report can be set up to print only failed 
measurements.
The syntax of the command is as follows:
list testcalls   detail | summary
[port UUCSSpp]
[grp group#] [to-grpgroup#]
[mem member#] [to-memmember#]
[resultresultID> | not-resultresultID]
[count#]  [print | schedule]
Error Code
This numerical code indicates the reason for a failure 
or abort. The codes are explained in the CO-TRK and 
TIE-TRK sections of 
Chapter 9, ‘‘ABRI-PORT (ASAI 
ISDN-BRI Port)’’
.