Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Additional Maintenance Procedures 
6-47
Automatic Transmission Measurement System (ATMS) 
6
Input Parameters - List Testcall Command
ATMS Summary Reports
The ATMS Summary Report summarizes, on a trunk group basis, the collective 
results of the latest ATMS tests performed on each trunk group. By interacting 
with the trunk group form, it highlights out-of-tolerance measurements. Marginal 
trunks are highlighted, and unusable trunks blink, allowing you to quickly identify 
out-of-tolerance or unusable trunks. 
Screen 6-2
 shows a typical summary report.
detail 
This qualifier specifies a detailed report that shows each measurement 
made for each trunk. 
summary 
This qualifier specifies a report that shows totaled results of ATMS tests 
for trunk groups as a whole. 
grp # 
This qualifier specifies a report showing measurements for a specific 
trunk group. When used with to-grp, this option specifies the starting 
trunk group in a range.
to-grp 
This qualifier specifies a report showing measurements for all trunk 
groups from 1 up to the trunk group number entered. When used with 
grp, this is the ending trunk group in a range.
mem Used 
with 
grp, this qualifier specifies a report showing measurements for 
a specific trunk group member. When used with to-mem, this is starting 
trunk group member in a range.
to-mem 
Used with grp, this qualifier specifies display of measurements for all 
trunk group members from 1 up to the specified trunk group member 
entered. When used with mem, this is the ending trunk group member in 
a range.
port 
This qualifier specifies display of measurements for the trunk assigned to 
a specific port circuit.
result 
Only measurements that match the specified result are displayed. Result 
IDs include passmargfail, and numerical abort codes.
not-result 
Only measurement results that do not match the specified result are 
displayed.
count number 
This qualifier limits the total number of records displayed.
print 
With this qualifier, the command executes immediately (if resources are 
available) and sends output both to the screen and to a printer 
connected to the terminal where the command was entered.
schedule 
With this qualifier, a scheduling form is displayed which allows you to 
specify a start time for the command. The command is placed in the 
queue and, when executed, sends the output to the system printer.