Lucent Technologies Release 7 User Manual
DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Architecture
1-9
How to use the Maintenance book
1
Screen 1-4.
Test Results screen
15. Find the Port Diagnostic Test (#35) [from the
Test No.
field) in the
DID-TRK section of the Maintenance book. Note the
Error Code
(61472).
16. Look in
Table 1-3
for Test #35 and then find “61472” in the Error Code
column
and “FAIL” in the Test Result column read the
Description/Recommendation column.
17. Perform both steps in the Description/Recommendation column.
18. Test the port (test port 01C1008 long and press
Enter
.) again after all of
the recommendations are exhausted.
19. If all tests pass, wait approximately 3-5 minutes for the Alarm and Error
logs to clear.
20. Type display alarms and press
Enter
twice.
21. Check that the DID-TRK alarm does not appear in the log.
Field descriptions
Table 1-3. TEST #35 Port Diagnostic Test
Error
Code
Code
Test
Result
Description/Recommendation
61472
FAIL
Battery feed test failed. A problem with the incoming CO line was
detected.
detected.
1. Check the incoming CO line for proper operation. If warranted, refer
the problem to the CO.
2. If the CO line checks out Ok, the failure must be on the DID port.
Replace the circuit pack.
Continued on next page
Error type
Enter error type, or blank
Error List
active-alarms, errors, or cleared-errors
Interval
h(our), d(ay), w(eek), m(onth), a(ll)
From:/To:
Specify time interval by date and time
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
01C1008 DID-TRK 35 FAIL 61472
01C1008 DID-TRK 35 FAIL 61472