Maintenance Commands 
8-92
display errors 
8
Output
Error Log Report Standard Resolution
Port
The physical location of the alarmed object. For circuit pack based 
MOs, the location is cabinet-carrier-[slot]-[circuit]. For PN-based 
objects, such as TDM-BUS, the location displays as 
3PN xx
, where xx 
is the PN number. For Fiber Link-based objects, the location displays as 
x a,b-PNC
 where x is the Fiber Link number and a- or b-pnc indicates 
one of the PNC pair. (Always a-pnc on systems with simplex PNC.)
Maintenance
Name
The abbreviated name of the MO that encountered the error.
Alt Name
An alternate means of identifying the MO. 
Error Type
Numerical error code that identifies the type of problem. The meanings 
of these codes are explained under the name of the MO in Chapter 9.
Aux Data
Additional numerical information about the error type. Only the most 
recent auxiliary data for each error type is displayed.
First Occur
Month, day, hour, and minute (and second if the high-resolution 
command line option is used) that the error was first recorded.
 
 display errors                                      Page   1 of   1
 
                                  ERROR REPORT
 
      The following options control which errors will be displayed.
          ERROR TYPES
 
             Error Type: ____          Error List: active-alarms
 
 
          REPORT PERIOD
             Interval: _      From: __/__/__:__ To: __/__/__:__
 
 
          EQUIPMENT TYPE ( Choose only one, if any, of the following )
 
                              Cabinet: __
                         Port Network: __
                         Board Number: ____
                                 Port: ______
                             Category: ________
                            Extension: _____
               Trunk ( group/member ): __/__