Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Architecture 
1-20
SPE Duplication 
1
As shown in 
Figure 1-7
, all maintenance capabilities for the standby SPE are built 
upon these three strategies.
Figure 1-7.
Components of Standby Maintenance
Standby SPE maintenance software is designed to attempt to self-correct 
problems. If a problem occurs, this software automatically tries to address the 
problem, bring the standby SPE back to a state of availability and clear all alarms 
which might have been raised. Typically, if a standby SPE problem has not 
cleared, it is of a hardware nature and some type of hardware component 
maintenance or replacement action is indicated. Once such corrections have 
been made, the system software will automatically bring the standby SPE back to 
full availability. There is no management terminal command to stimulate refresh of 
standby SPE memory; system software automatically accomplishes this itself 
when conditions are appropriate. The same is true of efforts to turn on shadowing 
where no explicit user interface command to turn on/off shadowing is available 
(note that busyout/release, below, can be used to indirectly accomplish this).
Standby Maintenance Monitor Software
The Standby Maintenance Monitor (SMM) is a software package that is 
always 
running on key components of the standby SPE to verify its competence. SMM 
tests individual standby SPE components and reports back to the active SPE, by 
the handshake message, any failures of individual tests. Failure reports trigger 
enhanced maintenance attention to standby SPE component problems by active 
Standby SPE
Hardware Status
Reading
Maintain
Handshake
Communication
Maintain
Standby SOH,
Shadowing,
Lock
Status
Memory
Shadowing
Memory
Refresh
G3-MT
Access to
Standby SPE
Components
Error/Alarm
Logging
for Standby
Components
Handshake
Comm. Up
Time of day
clocks
in synch
Handshake
Comm.Down
Stby SPE
down/lock
G3-MT
Access to
SPE-Down
Interface