Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Architecture 
1-21
SPE Duplication 
1
SPE software. SMM also ensures that when handshake communication has been 
down for an extended period, the standby SPE will transition into the SPE-down 
state.
Handshake Communication
Every 30 seconds, the active SPE sends a handshake request message to SMM 
and waits for SMM to respond with a handshake response message. This 
message transmission occurs across the Duplication Interface circuit packs and 
their interconnecting cable. As long as SMM responds to these regular 
handshake request messages, handshake communication is considered 
up as 
reported on the status spe screen.
The physical path of handshake communication is illustrated below. Hardware 
problems at any point in this route could interfere with handshake 
communication. If the standby SPE fails to respond to four successive 
handshake requests, handshake communication is considered down. A major 
alarm is logged against STBY-SPE with error type 1 logged. The status spe 
screen will indicate that handshake is down. It is then no longer possible to 
communicate with the standby SPE. Maintenance testing of the standby by the 
active SPE (or by command) is discontinued, and the error and alarm logs 
become outdated for standby components.
Handshake communication failure is a severe and rare condition. It is due to 
either a failure of Duplication Interface hardware or a catastrophic failure of the 
standby SPE. As long as the active SPE is not locked by the switches, software 
attempts every 30 seconds, to re-establish handshake communication.
When the SPEs are locked with the switches, handshake communication is 
physically impossible, but no alarm is raised. When the standby is busied out, 
handshake communication should remain up, but in any case, only the busyout 
WARNING alarm will be raised.
Whenever the active SPE has undergone a restart (levels 1-5), handshake is 
technically considered down during and just after the restart. After a level 1 (hot) 
restart, if there are no standby SPE problems, handshake communication should 
be restored within 30 seconds. After active-SPE restarts of levels 2 and up, 
handshake should be restored within 3 minutes of G3-MT re-enabling.
The active SPE keeps hardware configuration and vintage data about the 
components of the standby SPE. This data can be accessed with list 
configuration control
. Whenever handshake is down, this data may be out of 
date. Whenever handshake has been down and is restored, the active SPE 
requests standby SPE software to transmit the current version of this data. The 
data is then stored in active SPE memory. 
Failure to use the lock-and-power- down method for standby circuit pack 
replacement can lead to incorrect standby component hardware configuration 
and vintage data.