Maintenance Commands 
8-182
reset interchange 
8
Both demand and spontaneous PNC interchanges are prevented by the 
following conditions:
The standby PNC is busied out.
The PNCs are locked by means of the set pnc lock or reset PNC 
override-and-lock
 commands.
For five minutes after a spontaneous PNC interchange, or for 30 seconds 
after a demand interchange, an anti-thrashing mechanism prevents 
subsequent interchanges unless the override-and-lock option is used.
If the state of health of the standby PNC is worse than that of the active, 
the command will abort unless the override-and-lock option is used.
If the standby PNC has not completed a global refresh since it was last 
initialized or released, the reset will abort unless the override-and -lock 
option is used.
Note the following caution regarding the use of the override-and-lock option.
See status pnc for details of how to obtain and interpret the states of health and 
other current information about the PNCs. For a more complete explanation of 
PNC duplication and interchanges, see PNC-DUP in Chapter 9.
Parameters
interchange
”interchange” (without a preceding hyphen) must be specified on 
the command line.
override-and-lock
This option is also used to override the anti-thrashing mechanism. 
Subsequent PNC interchanges are prevented, regardless of 
changes in the states health of the PNCs. Double call setup still 
takes place; each call is set up on both PNCs. To unlock the PNCs, 
use set pnc unlock.
!
CAUTION:
This option forces execution of the interchange regardless of 
the state of health of the standby, possibly disrupting service.