DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Architecture 
1-24
SPE Duplication 
1
Locking the Active SPE
Duplication Interface hardware supports the ability to lock the active SPE in 
active mode by means of the SPE-Select switches. The procedure for safely 
doing this is described in 
Chapter 5, ‘‘Alarms, Errors, and Troubleshooting’’
, and 
in 
‘‘STBY-SPE (Standby SPE Maintenance)’’
 in 
Chapter 9, ‘‘Maintenance Object 
Repair Procedures’’
. In locked mode, the system operates as if it is simplex:
The standby SPE is inaccessible to the active SPE and active G3-MT 
login.
No SPE-interchange is possible.
Handshake is down and memory shadowing is off.
The locked state is intended for temporary use to prevent interchanges during 
maintenance sessions. No alarm is raised when the switches are locked. 
However, alarms against SPE-SELE are raised later if the switches are left out of 
the AUTO position for an extended length of time.
Memory Shadowing
Memory shadowing is used to keep the standby SPE’s memory content 
up-to-date relative to the active SPE’s memory. Memory shadowing is turned on 
automatically when the standby SPE has booted up and completed its own 
memory testing. Each write operation in active memory is replicated in the 
corresponding location in standby memory.
Table 1-6.
Testability Requirements for Standby Components
Component
Required Condition
PROCR
handshake up
MEM-BD
handshake up
SW-CTL
handshake up
SYSAM
handshake up
PKT-INT
handshake up and Stby Refreshed
DUPINT
handshake up
DUP-CHL
handshake up
HOST-ADAPTER
handshake up
DISK
handshake up and Stby Refreshed
TAPE
handshake up and Stby Refreshed