Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Architecture 
1-25
SPE Duplication 
1
When shadowing into the standby SPE has been off (as when the system first 
comes up), system software checks to see if it is safe to restore shadowing. 
Handshake communication must be up. Then software verifies (with Test #920) 
that the SPEs have identical hardware configurations. If this passes and there are 
no shadow-relevant component failures, system software turns on shadowing 
again.
Once shadowing is turned on, it is necessary to refresh the contents of standby 
memory to bring it into full agreement with the active’s by copying every word of 
active SPE memory to the standby. This takes approximately 5 minutes, though 
traffic load can increase the duration. When completed, the standby SPE is said 
to be "refreshed". status spe or the 
Standby SPE Status Query Test (#855) in the 
STBY-SPE test sequence can be used to check the REFRESH status of the 
standby. Unless the standby SPE is refreshed, interchange into it can disrupt 
service for several minutes. Otherwise, interchanges are minimally disruptive. A 
standby SPE exiting lock mode or just released from busyout must undergo this 
full re-initialization.
System software tracks the operation and raises a major alarm when refresh 
failure occurs. If shadowing stays on, system software automatically tries to 
refresh again 5 minutes later.
Generally, memory shadowing should always remain on. But there are conditions 
when the system legitimately operates with shadowing off:
The standby SPE is undergoing any restart.
The active SPE is undergoing a restart level of 2 or greater.
The active SPE is locked.
The standby SPE is busied out.
In any other situation, it is an error condition for shadowing to be off. The first 2 
situations are transitory and shadowing should automatically be restored within 
10 minutes. If shadowing has been on for several minutes, it is an error condition 
for the standby not to be refreshed.
Initialization: Bringing the Standby SPE Up
When the standby SPE has been out of service or is first coming up, SPE 
software executes the following steps:
1. Establishes handshake communication.
2. When SMM answers handshake, raises the standby SPE’s SOH to 
not 
refreshed if it has no critical component alarms, or partially functional 
there are critical component alarms.
3. Tests for component mismatch (test number 920).
4. If there is no mismatch, and no major alarms against shadow-relevant 
components, and if SMM permits, turns on memory shadowing