Maintenance Commands 
8-212
set tone-clock 
8
Input Form
An input form with the following fields is displayed. The current time, or default 
time will be displayed in the fields.
set tone-clock
set tone-clock UUC [override]
On port networks with duplicated Tone-Clocks, this command is used to select 
which of the two Tone-Clock circuit packs is to be active.
In EPNs, the A-carrier Tone Clock is the 
preferred Tone-Clock. It is always active 
unless a failure, maintenance testing, or use of this set command has caused an 
interchange to the B-carrier Tone-Clock. If you have used this command during a 
maintenance session, set the EPN Tone-Clock back to the A carrier when you are 
finished, assuming it is healthy. Tone-Clock interchanges executed by scheduled 
daily maintenance cause the standby to become active for 20 seconds and then 
interchange back to whichever Tone-Clock was originally active.
Cabinet number defaults to 1.
Day of the Week:
Valid entries are Monday through Sunday.
Day of the Month:
1-31 are valid entries. A check for leap year is also made.
Month:
January through December.
Year:
The year must be saved as translation data and passed to the 
kernel whenever kernel memory is corrupted (system reboot or 
cold I restart), or the data is changed.
Hour:
0-23 are valid entries.
Minute:
0-59 are valid entries.
Second:
This field is reset automatically and cannot be altered.
 
 
 set time                                                   Page 1 of 1
                               DATE AND TIME
         DATE
 
             Day of the Week: _________      Month: _________
            Day of the Month: __              Year: ____
 
         TIME
                        Hour: __            Second:
                      Minute: __