Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Architecture 
1-28
Protocols 
1
power is restored, taking up to 15 minutes, depending on the size of the system. 
Human intervention may be required if central office equipment has been busied 
out.
EPN Cabinet with Power Holdover
When power is interrupted to an EPN MCC for less than 15 seconds, no service 
effect results. If the interruption exceeds 15 seconds, only the control carrier is 
kept up. Circuit packs on other carriers are powered down. Only calls and other 
services maintained by circuit packs on the control carrier are maintained. For 
this reason, critical services and those that require a long time to restore (for 
example, Announcement circuit packs) should be located on control carriers. All 
service to Port Networks connected to a Switch Node in the EPN is lost. When 
power is restored, all affected EPNs are reset by system software (see 
(Expansion Port Network)’’
 in 
Chapter 9, ‘‘Maintenance Object Repair 
Procedures’’
). As with the PPN, a warning alarm is raised against AC-POWER.
External Alarm Leads
Each cabinet provides two leads for one major and one minor alarm contact 
closure that can be connected to external equipment. These are located on the 
SYSAM and Maintenance circuit packs. If the switch is under warranty or a 
maintenance agreement, EXT-DEV alarms are generated by the equipment 
connected to these leads and reported to INADS. These may be used to report 
failures of UPSs or battery reserves powering the switch. They are also 
commonly used to monitor adjuncts such as AUDIX.
Protocols
This section describes the protocols handled by the system and the points where 
these protocols change
 is a pictorial guide through data- 
transmission state changes
 illustrates the flow of data from DTE 
equipment, like a terminal or host, through DCE equipment, like a modem or data 
module, into a communications port on the system. The data flow is shown by 
solid lines. Below these lines are the protocols used at particular points in the 
data stream.
Not shown in th
 is the treatment of D-channels in ISDN-PRI and 
ISDN-BRI transmissions. PRI and BRI D-channels transport information elements 
that contain call-signaling and caller information. These elements conform to 
ISDN level-3 protocol. In the case of BRI, the elements are created by the 
terminal or data module; for the PRI, the elements are created by the system, 
which inserts them into the D-channel at the DS1 port. 
For ISDN transmissions, therefore, BRI terminals and data modules, and DS1 
ports insert, interpret, and strip both layer-2 DCE information and layer-3 
elements. Also, the DS1 port passes layer-3 elements to the system for 
processing.