Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Commands 
8-271
status data-module 
8
status data-module
status data-module extension [print]
This command displays internal software states of a specified data-module port. 
It is useful for diagnosis and locating facilities to which the data module is 
connected.
0x64 (0t100)
ISDN protocol error
0x66 (0t102)
ISDN timer expired
0x7f (0t127)
Reason unknown
0xC2 (0t194)
Ring no answer
0xC8 (0t200)
Hi and dry - no feedback detected
0xC9 (0t201)
Cascade link administered wrong
0xCA (0t202)
CPTR not available to detect failure
Table 8-13. Status AC - Failure Cause Values — Continued
Failure Cause 
(hexadecimal)
Description
Continued on next page
                            DATA-MODULE STATUS
Data Ext/Stn Ext for Stn DM: 301             Service State: out-of-service
      Port/Channel Number: 01C1103     Maintenance Busy? no
       CF Destination Ext:
          Connected Ports:
              Associated C-LAN Modem: 1
                       Connect speed: 9600
                                  V42? yes
                               V42bis? no