Maintenance Commands 
8-272
status hardware-group 
8
Output
If the specified port is administered as a system port, the following fields will be 
displayed at the bottom of the screen. See PDATA-PT in 
Chapter 9
 for more 
information.
status hardware-group
status hardware-group [print]
Summary information on the active or last hardware group tests will be displayed. 
This display includes the number and percentage of maintenance objects tested, 
the percentage of tests passed/failed/aborted, the time elapsed since initiating 
the hardware group test, the specific hardware group test command (see test 
hardware-group command) initiated, and the state (active/canceled/complete) of 
the hardware-group test.
Data Ext/Sta 
Ext for Stn 
DM
The data module’s extension number. For DTDMs, the connected 
station extension is shown instead.
Port/Channel
Number
The location of the port connected to the data module. For data 
channels, the channel number is shown instead.
Service 
State
The operational state of the data-module:
in-service/idle
 The data module is connected but not in use.
in-service/active
 The data module is connected and in use.
out-of-service
 The data module has been removed from service.
CF Destination 
Ext
The call-forwarding destination, if any, of the port.
Maintenance 
Busy
Whether the port is busied out for testing.
Connected Ports
Locations of ports to which the data module is currently 
connected.
Associated 
PDATA Port
The location of a port on a TN553 Packet Data Line circuit pack to 
which this data-module port is connected.
Service State
The operational state of the associated PDATA port.
Maintenance 
Busy