Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Commands 
8-309
status synchronization 
8
The following display shows a typical result when status switch-node is entered.
status synchronization
This command lists the synchronization source for the system.
Mode
The mode is the current role of the switch node carrier. A mode of 
"active" means the SN is providing normal circuit and control functions 
for PNC. A mode of "standby" means the SN is ready to become active, 
but is currently not active. If blanks are displayed it means that PNC is 
not duplicated.
Major 
Alarms
The number of major alarms logged against the switch node carrier that 
is being displayed.
Minor 
Alarms
The number of minor alarms logged against the switch node carrier that 
is being displayed.
Warning 
Alarms
The number of warning alarms logged against the switch node carrier 
that is being displayed.
Active SNC 
Location
The physical position of the active switch node Clock circuit pack, per 
administration, represented as "UUcSS." "UU" represents the cabinet 
number, "c" represents the carrier, and "SS" represents the slot position. 
If an SNC is administered but not inserted, "no board" will be displayed.
Standby SNC 
Location
The physical position of the standby switch node Clock circuit pack, 
per administration, represented as "UUcSS." "UU" represents the 
cabinet number, "c" represents the carrier, and "SS" represents the slot 
position. Blanks will be displayed if there is no standby switch node 
Clock for a given switch node. If an SNC is administered but not 
inserted, "no board" will be displayed.
Action/ Object
Qualifier
Qualifier Description
Permissions
Defaults
Feature
Interactions
status synchronization
print
init
inads
craft
none
none
 
 status switch-node 1                                               page 1 of 1
 
                                switch node STATUS
 
                                Major   Minor   Warning  Active SNC  Standby SNC
 Switch Node  Location  Mode    Alarms  Alarms  Alarms   Location    Location
 
  1  A-PNC      01E     active    0       0       0      01E10       01E12
  1  B-PNC      01D     standby   0       1       2      01D10       01D12