Maintenance Commands
8-309
status synchronization
8
The following display shows a typical result when status switch-node is entered.
status synchronization
This command lists the synchronization source for the system.
Mode
The mode is the current role of the switch node carrier. A mode of
"active" means the SN is providing normal circuit and control functions
for PNC. A mode of "standby" means the SN is ready to become active,
but is currently not active. If blanks are displayed it means that PNC is
not duplicated.
"active" means the SN is providing normal circuit and control functions
for PNC. A mode of "standby" means the SN is ready to become active,
but is currently not active. If blanks are displayed it means that PNC is
not duplicated.
Major
Alarms
The number of major alarms logged against the switch node carrier that
is being displayed.
is being displayed.
Minor
Alarms
The number of minor alarms logged against the switch node carrier that
is being displayed.
is being displayed.
Warning
Alarms
The number of warning alarms logged against the switch node carrier
that is being displayed.
that is being displayed.
Active SNC
Location
The physical position of the active switch node Clock circuit pack, per
administration, represented as "UUcSS." "UU" represents the cabinet
number, "c" represents the carrier, and "SS" represents the slot position.
If an SNC is administered but not inserted, "no board" will be displayed.
administration, represented as "UUcSS." "UU" represents the cabinet
number, "c" represents the carrier, and "SS" represents the slot position.
If an SNC is administered but not inserted, "no board" will be displayed.
Standby SNC
Location
The physical position of the standby switch node Clock circuit pack,
per administration, represented as "UUcSS." "UU" represents the
cabinet number, "c" represents the carrier, and "SS" represents the slot
position. Blanks will be displayed if there is no standby switch node
Clock for a given switch node. If an SNC is administered but not
inserted, "no board" will be displayed.
per administration, represented as "UUcSS." "UU" represents the
cabinet number, "c" represents the carrier, and "SS" represents the slot
position. Blanks will be displayed if there is no standby switch node
Clock for a given switch node. If an SNC is administered but not
inserted, "no board" will be displayed.
Action/ Object
Qualifier
Qualifier Description
Permissions
Defaults
Feature
Interactions
Interactions
status synchronization
print
init
inads
craft
inads
craft
none
none
status switch-node 1 page 1 of 1
switch node STATUS
Major Minor Warning Active SNC Standby SNC
Switch Node Location Mode Alarms Alarms Alarms Location Location
1 A-PNC 01E active 0 0 0 01E10 01E12
1 B-PNC 01D standby 0 1 2 01D10 01D12