Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Commands 
8-310
status sys-link 
8
Output
The following example shows the output for the status synchronization 
command.
status sys-link
status sys-link UUCSSpp [ channel channel# ] [print]
The status sys-link command displays status data for a specified system link. The 
report includes the type and operational state of the link, the associated 
processor channel, if any, active alarms and path status, and a list of all hardware 
components making up the link’s path. If in addition to the current path a faulted 
path exists, the components making up the faulted path are displayed on page 2 
of the report.
Parameters
Examples
status sys-link 1e0201
status sys-link 1c17 channel 2
Output
UUCSSpp
The link is specified by giving the location of the port associated with the 
link.
channel#
If the link is an X.25 link (to an adjunct or another switch), you must specify a 
processor channel number (1-128) associated with the link.
Location
The location of the port associated with the system link 
(cabinet-carrier-slot-circuit).
status synchronization                                                     SPE B
                          SYNCHRONIZATION STATUS
                Stratum Level: 4
      Inferred Sync Reference: UDS1-BD     Location: 01C20     
Excessive Reference Switching: No